DeviceNetACON-C/CGPCON-C/CG/CA/CFASCON-CAOperation Manual, Third Edition

Seite 2

4 No. Operation Description Description 4 Installation and Start (4) Safety Measures  When the work is carried out with 2 or more persons, make

Seite 3 - [Important]

3. PCON-CA/CFA 94 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 PCON-CA/CFA DI (port number) PLC

Seite 4

3. PCON-CA/CFA 95 (3) I/O signal assignments The signals assigned to the controller’s I/O ports vary depending on the setting of parameter No. 25.

Seite 5 - Table of Contents

3. PCON-CA/CFA 96 Setting of Parameter No. 25 512-point mode Solenoid mode 1 Solenoid mode 2 3 4 5 Category Port No. Symbol Signal name Symbo

Seite 6

3. PCON-CA/CFA 97 3.7.3 Position/Simple Direct Mode (Number of Occupied Channels: 4) In this mode, the actuator is operated by specifying position

Seite 7 - Safety Guide

3. PCON-CA/CFA 98 1 word (channel) = 16 bitsTarget position (lower word) Target position (upper word) If the target position is a negative value, it

Seite 8

3. PCON-CA/CFA 99 1 word (channel) = 16 bits Current position (lower word) Current position (upper word) Completed position number Status signal If

Seite 9

3. PCON-CA/CFA 100 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0

Seite 10

3. PCON-CA/CFA 101 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbo

Seite 11

3. PCON-CA/CFA 102 3.7.4 Half Direct Mode (Number of Occupied Channels: 8) In this mode, the target position, positioning band, speed, acceleratio

Seite 12

3. PCON-CA/CFA 103 (2) I/O signal assignments for each axis The I/O signals of each axis consist of eight input words (channels) and eight output

Seite 13 - Alert Indication

5 No. Operation Description Description 6 Trial Operation  When the work is carried out with 2 or more persons, make it clear who is to be the

Seite 14

3. PCON-CA/CFA 104 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative value,

Seite 15 - 1. Overview

3. PCON-CA/CFA 105 PLC input Channel (* n indicates the node address of each axis.) 1 word (ch

Seite 16 - Communication

3. PCON-CA/CFA 106 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0

Seite 17 - 2. ACON-C/CG, PCON-C/CG

3. PCON-CA/CFA 107 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbo

Seite 18

3. PCON-CA/CFA 108 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbo

Seite 19 - 2.2 Model Numbers

3. PCON-CA/CFA 109 3.7.5 Full Direct Mode (Number of Occupied Channels: 16) In this mode, the actuator is operated by specifying all values relati

Seite 20 - 2.3 Interface Specifications

3. PCON-CA/CFA 110 (2) I/O signal assignments for each axis The I/O signals of each axis consist of sixteen input words (channels) and sixteen out

Seite 21 - 2.4.1 Name of Each Part

3. PCON-CA/CFA 111 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative value,

Seite 22

3. PCON-CA/CFA 112 Channel (* n indicates the node address of each axis.) 1 word (channel) = 16 bi

Seite 23

3. PCON-CA/CFA 113 PLC input Channel (* n indicates the node address of each axis.) 1 word (chann

Seite 24

6 No. Operation Description Description 8 Maintenance and Inspection  When the work is carried out with 2 or more persons, make it clear who is

Seite 25

3. PCON-CA/CFA 114 Address (* “n” shows the head register address per each axis). one word = 16 bits n+10 b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5

Seite 26

3. PCON-CA/CFA 115 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0

Seite 27

3. PCON-CA/CFA 116 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Symbol Fun

Seite 28

3. PCON-CA/CFA 117 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Symbol Fun

Seite 29

3. PCON-CA/CFA 118 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbo

Seite 30

3. PCON-CA/CFA 119 Signal type Bits Symbol Description Details b15 EMGS Emergency stop: An emergency stop is actuated when this signal turns ON

Seite 31

3. PCON-CA/CFA 120 3.7.6 Remote I/O Mode 2 (Number of Occupied Channels: 6) In this mode, the actuator is operated by specifying position numbers,

Seite 32

3. PCON-CA/CFA 121 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 PCON-CA/CFA DI and input register

Seite 33

3. PCON-CA/CFA 122 1 word (channel) = 16 bits Controller output port number Not available. Current position (lower word) Current position (upper wor

Seite 34

3. PCON-CA/CFA 123 (3) I/O signal assignments For the signal assignments corresponding to each PIO pattern, refer to the I/O signal assignments fo

Seite 35

7 Alert Indication The safety precautions are divided into “Danger”, “Warning”, “Caution” and “Notice” according to the warning level, as follows

Seite 36

3. PCON-CA/CFA 124 3.7.7 I/O Signal Controls and Functions * ON indicates that the applicable bit signal is “1,” while OFF indicates that the bit

Seite 37

3. PCON-CA/CFA 125 (5) Servo ON command (SON) [PLC output signal] Ready (SV) [PLC input signal] When the SON signal is turned ON, the servo will

Seite 38

3. PCON-CA/CFA 126 (6) Home return (HOME) [PLC output signal] Home return complete (HEND) [PLC input signal] Home return in progress (GHMS) [PL

Seite 39

3. PCON-CA/CFA 127 (7) Positioning start (CSTR): Used in the position/simple direct mode [PLC output signal] The CSTR command is processed at the

Seite 40

3. PCON-CA/CFA 128 (10) Position complete signal (PEND) [PLC input signal] This signal turns ON after the actuator has moved to the target position

Seite 41

3. PCON-CA/CFA 129 (12) Zone 1 (ZONE1) [PLC input signal] Zone 2 (ZONE2) [PLC input signal] Position zone (PZONE) [PLC input signal] Each signal

Seite 42

3. PCON-CA/CFA 130 (13) +Jog (JOG+) [PLC output signal] -Jog (JOG-) [PLC output signal] These signals are used as starting commands for jog opera

Seite 43

3. PCON-CA/CFA 131 (14) Jog-speed/inch-distance switching (JVEL) [PLC output signal] This signal is used to switch between the jog speed parameter

Seite 44

3. PCON-CA/CFA 132 (16) Teaching command (MODE) [PLC output signal] Teaching mode signal (MODES) [PLC input signal] When the MODE signal is turne

Seite 45

3. PCON-CA/CFA 133 (19) Operation mode (RMOD) [PLC output signal] Operation mode status (RMDS) [PLC input signal] The operation mode is selected

Seite 47

3. PCON-CA/CFA 134 (23) Load missed in push motion (PSFL) [PLC input signal] This signal turns ON when the actuator has not contacted the load in p

Seite 48

3. PCON-CA/CFA 135 (26) Load output judgment (LOAD) [PLC input signal] This signal is effective only during push-motion operation. To use the LOAD

Seite 49

3. PCON-CA/CFA 136 (27) Torque level (TRQS) [PLC input signal] This signal is effective only during push-motion operation. If the motor current rea

Seite 50

3. PCON-CA/CFA 137 (28) Stopping control mode (SMOD) [PLC output signal] One general characteristic of pulse motors is that their holding current a

Seite 51

3. PCON-CA/CFA 138 (29) Acceleration/deceleration mode (MOD1, MOD0) [PLC output signal] These signals are used to select the acceleration/decelerat

Seite 52

3. PCON-CA/CFA 139 (30) Stop Mode Selection (ASO1, ASO0) [PLC Output Signal] Select the stop mode for the duration before the movement to the next

Seite 53

3. PCON-CA/CFA 140 3.8 I/O Signal Timings The maximum response time after a control signal is turned ON to operate the ROBO Cylinder in a PLC sequ

Seite 54

3. PCON-CA/CFA 141 3.9 Operation This section describes the timings of basic operations in the position/simple direct mode, half direct mode and f

Seite 55

3. PCON-CA/CFA 142 Set value of target position data (PLCPCON) [1] [2] [3] [4] [5][6] Specified po

Seite 56

3. PCON-CA/CFA 143 (2) Operation in the half direct mode The actuator is operated by specifying the data to the target position channel, positioni

Seite 57

1. Overview 9 1. Overview The open field network DeviceNet is a multi-bit, multi-vendor network for communication of both control and data signals

Seite 58

3. PCON-CA/CFA 144 [1] [2] [3] [4] [5] [6] [7] [8] [9] [10][14][13][12][11] *T1: Make sure “T1 t 0 ms” is satisfied by considering the scan time of

Seite 59

3. PCON-CA/CFA 145 (3) Operation in the full direct mode The actuator is operated by specifying all conditions required for positioning to channel

Seite 60

3. PCON-CA/CFA 146 [1] [2] [3] [4] [5] [6] [7] [8] Set value of target position data (PLCPCON) Set value of positioning band data (PLCPCON) Set

Seite 61

3. PCON-CA/CFA 147 Push-motion specification PUSH (PLCPCON) PushPositioning band *T1: Make sure “T1 t 0

Seite 62

3. PCON-CA/CFA 148 Speed n2Speed n3 [1] [2][3] (4) Data change during movement In the half direct mode or full direct mode, the value currently set

Seite 63

3. PCON-CA/CFA 149 3.10 DeviceNet Parameters Parameters relating to DeviceNet are Nos. 84 to 87, 90 and 159. Category: C: External interface param

Seite 64

3. PCON-CA/CFA 150 z Network type (No. 87, NTYP) The network module type is specified in parameter No. 87. Do not change the default setting. z

Seite 65

3. PCON-CA/CFA 151 (Example ii) Set value = “1” z indicates ON, while O indicates OFF. PCON Input register Hex

Seite 66

3. PCON-CA/CFA 152 PCON Input register Hexa decimal data Output channel Hexa decimal data PCON Output register Input channel Hexa decimal data Hexa

Seite 67

3. PCON-CA/CFA 153 (Example iv) Set value = “3” z indicates ON, while O indicates OFF. z FB Half Direct Mode Sp

Seite 68

2. ACON-C/CG, PCON-C/CG 10 PLC PLC Flat cable Communication cable 2. ACON-C/CG, PCON-C/CG 2.1 Operation Modes and Functions ACON and PCON contro

Seite 69

3. PCON-CA/CFA 154 3.11 Troubleshooting z Alarm messages, causes and remedial actions If an alarm occurs, a corresponding simple alarm code will

Seite 70

3. PCON-CA/CFA 155 3.12 CE Mark If a compliance with the CE Marking is required, please follow Overseas Standards Compliance Manual (ME0287) that

Seite 71

4. SCON-CA 156 PLC PLC Flat cable Communication cable 4. SCON-CA 4.1 Operation Modes and Functions SCON-CA controllers supporting DeviceNet can b

Seite 72

4. SCON-CA 157 [2] Position/simple direct mode: In this mode, the actuator is operated by specifying position numbers. You can select whether to s

Seite 73 - 2.8 I/O Signal Timings

4. SCON-CA 158 Communication cable Flat cable Target position: 100.00 mmPositioning band: 0.10 mmSpeed specification: 100.0 mm/sec Acceleration:

Seite 74 - 2.9 Operation

4. SCON-CA 159 Flat cable Communication cable [7] Half direct mode 2: In this mode, the actuator is operated by specifying the speed, acceleration

Seite 75

4. SCON-CA 160 4.2 Model Numbers The model numbers of SCON-CA controller supporting DeviceNet are indicated as follows, respectively: z SCON-CA--

Seite 76

4. SCON-CA 161 4.3 Interface Specifications Item Specification DeviceNet 2.0 Group 2 only server Communication protocol Network-powered isolation

Seite 77

4. SCON-CA 162 Monitor LEDs DeviceNet communication connector PCB side : MSTBA2.5/5-G-5.08AU (PHOENIX CONTACT) Cable side : SMSTB2.5/5-ST-5.08AUM

Seite 78

4. SCON-CA 163 4.4.2 Monitor LED Indicators The two LEDs, MS and NS, provided on the front panel of the controller are used to check the node (con

Seite 79

2. ACON-C/CG, PCON-C/CG 11 [2] Position/simple direct mode: In this mode, the actuator is operated by specifying position numbers. You can select

Seite 80

4. SCON-CA 164 4.5 Selecting (Setting) the Operation Mode The operation mode is set using a parameter. Set the mode selector switch on the front

Seite 81

4. SCON-CA 165 4.7 Communicating with the Master Station 4.7.1 Operation Modes and Corresponding PLC I/O Areas The channel assignments in each m

Seite 82 - 2.10 DeviceNet Parameters

4. SCON-CA 166 x PLC output o SCON-CA input side (* n indicates the node address of each axis.) SCON-CA DI and input data register Position/simple

Seite 83

4. SCON-CA 167 x SCON-CA output o PLC input side (* n indicates the node address of each axis.) SCON-CA DO and output data register Remote I/O mod

Seite 84

4. SCON-CA 168 x SCON-CA output o PLC input side (* n indicates the node address of each axis.) SCON-CA DO and input data register Position/simple

Seite 85

4. SCON-CA 169 4.7.2 Remote I/O Mode (Number of Occupied Channel: 1) In this mode, the actuator is operated by specifying position numbers just l

Seite 86

4. SCON-CA 170 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 SCON-CA DI (port number) PLC outpu

Seite 87 - 2.11 Troubleshooting

4. SCON-CA 171 (3) I/O signal assignments The signals assigned to the controller’s I/O ports vary depending on the setting of parameter No. 25. (F

Seite 88 - 2.12 CE Mark

4. SCON-CA 172 Setting of Parameter No. 25 512-point mode Solenoid mode 1 Solenoid mode 2 3 4 5 Category Port No. Symbol Signal name Symbol S

Seite 89

4. SCON-CA 173 Setting of Parameter No. 25 Force control mode 1 Force control mode 2 6 7 Category Port No. Symbol Signal name Symbol Signal na

Seite 90

2. ACON-C/CG, PCON-C/CG 12 䎳䎯䎦䎃Flat cable Communication cable [4] Full direct mode: In this mode, the actuator is operated by specifying all value

Seite 91

4. SCON-CA 174 4.7.3 Position/Simple Direct Mode (Number of Occupied Channels: 4) In this mode, the actuator is operated by specifying position nu

Seite 92 - 3.2 Model Numbers

4. SCON-CA 175 1 word (channel) = 16 bitsTarget position (lower word) Target position (upper word) If the target position is a negative value, it is

Seite 93 - 3.3 Interface Specifications

4. SCON-CA 176 1 word (channel) = 16 bits Current position (lower word) Current position (upper word) Completed position number Status signal If th

Seite 94 - 3.4.1 Name of Each Part

4. SCON-CA 177 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Seite 95

4. SCON-CA 178 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Seite 96

4. SCON-CA 179 4.7.4 Half Direct Mode (Number of Occupied Channels: 8) In this mode, the target position, positioning band, speed, acceleration/de

Seite 97

4. SCON-CA 180 (2) I/O signal assignments for each axis The I/O signals of each axis consist of eight input words (channels) and eight output word

Seite 98

4. SCON-CA 181 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative value, it i

Seite 99

4. SCON-CA 182 PLC input Channel (* n indicates the node address of each axis.) 1 word (channel

Seite 100 - 3. PCON-CA/CFA

4. SCON-CA 183 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Seite 101 - (3) I/O signal assignments

2. ACON-C/CG, PCON-C/CG 13 2.2 Model Numbers The model numbers of ACON and PCON controller supporting DeviceNet are indicated as follows, respecti

Seite 102

4. SCON-CA 184 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Seite 103

4. SCON-CA 185 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Seite 104

4. SCON-CA 186 4.7.5 Full Direct Mode (Number of Occupied Channels: 16) In this mode, the actuator is operated by specifying all values relating t

Seite 105

4. SCON-CA 187 (2) I/O signal assignments for each axis The I/O signals of each axis consist of sixteen input words (channels) and sixteen output

Seite 106

4. SCON-CA 188 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative value, it i

Seite 107

4. SCON-CA 189 Channel (* n indicates the node address of each axis.) 1 word (channel) = 16 bits Zo

Seite 108

4. SCON-CA 190 PLC input Channel (* n indicates the node address of each axis.) 1 word (channel) = 16 bits

Seite 109

4. SCON-CA 191 6!$ 6 6 6 6 6 6% 6$ 6# 6" 6! 6 6 6 6 6#"$"$ $% %" $ !!"$&

Seite 110

4. SCON-CA 192 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Seite 111

4. SCON-CA 193 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Symbol Functio

Seite 113

2. ACON-C/CG, PCON-C/CG 14 2.3 Interface Specifications Item Specification DeviceNet 2.0 Group 2 only server Communication protocol Network-power

Seite 114

4. SCON-CA 194 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Symbol Functio

Seite 115

4. SCON-CA 195 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Seite 116

4. SCON-CA 196 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Seite 117

4. SCON-CA 197 4.7.6 Remote I/O Mode 2 (Number of Occupied Channels: 6) In this mode, the actuator is operated by specifying position numbers, jus

Seite 118

4. SCON-CA 198 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 SCON-CA DI and input register PLC out

Seite 119

4. SCON-CA 199 1 word (channel) = 16 bits Controller output port number Not available. Current position (lower word) Current position (upper word) C

Seite 120

4. SCON-CA 200 (3) I/O signal assignments For the signal assignments corresponding to each PIO pattern, refer to the I/O signal assignments for th

Seite 121

4. SCON-CA 201 4.7.7 Position/Simple Direct Mode 2 (Number of Occupied Channels: 4) In this mode, the actuator is operated by means of force contr

Seite 122 - Acceleration

4. SCON-CA 202 1 word (channel) = 16 bitsTarget position (lower word) Target position (upper word) If the target position is a negative value, it is

Seite 123

4. SCON-CA 203 1 word (channel) = 16 bits Current position (lower word) Current position (upper word) Completed position number Status signal If th

Seite 124

2. ACON-C/CG, PCON-C/CG 15 Status LEDs Monitor LEDs DeviceNet communication connector PCB side : MSTBA2.5/5-G-5.08AUM (PHOENIX CONTACT) Cable side

Seite 125

4. SCON-CA 204 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Seite 126

4. SCON-CA 205 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Seite 127

4. SCON-CA 206 4.7.8 Half Direct Mode (Number of Occupied Channels: 8) In this mode, the actuator is operated by means of force control (push-mot

Seite 128

4. SCON-CA 207 (2) I/O signal assignments for each axis The I/O signals of each axis consist of eight input words (channels) and eight output word

Seite 129

4. SCON-CA 208 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative value, it i

Seite 130

4. SCON-CA 209 PLC input Channel (* n indicates the node address of each axis.) 1 word (channel

Seite 131

4. SCON-CA 210 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Seite 132

4. SCON-CA 211 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Seite 133 - [PLC output signal]

4. SCON-CA 212 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bits Symbol D

Seite 134

4. SCON-CA 213 4.7.9 Remote I/O Mode 3 (Number of Occupied Channels: 6) In this mode, the actuator is operated by means of force control (push-mo

Seite 135

2. ACON-C/CG, PCON-C/CG 16 2.4.2 Monitor LED Indicators The two LEDs, MS and NS, provided on the front panel of the controller are used to check t

Seite 136

4. SCON-CA 214 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 SCON-CA DI and input register PLC out

Seite 137

4. SCON-CA 215 1 word (channel) = 16 bits Controller output port number Not available. Current position (lower word) Current position (upper word)

Seite 138

4. SCON-CA 216 (3) I/O signal assignments For the signal assignments corresponding to each PIO pattern, refer to the I/O signal assignments for th

Seite 139

4. SCON-CA 217 4.7.10 Half Direct Mode 3 (Number of Occupied Channels: 8) In this operation mode, the jog function available in the half numerica

Seite 140

4. SCON-CA 218 (2) I/O signal assignments for each axis The I/O signals of each axis consist of eight input words (channels) and eight output word

Seite 141

4. SCON-CA 219 MOD1 MOD0 Target position (lower word) Target position (upper word) If the target position is a negative value, it is indicated by a

Seite 142

4. SCON-CA 220 PLC input Channel (* n indicates the node address of each axis.) 1 word (chann

Seite 143

4. SCON-CA 221 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Seite 144

4. SCON-CA 222 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”) Signal type Bit

Seite 145

4. SCON-CA 223 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”) Signal type Bit

Seite 146 - 3.8 I/O Signal Timings

2. ACON-C/CG, PCON-C/CG 17 2.5 Selecting (Setting) the Operation Mode The operation mode is set using a parameter. Set the mode selector switch o

Seite 147 - 3.9 Operation

4. SCON-CA 224 4.7.11 I/O Signal Controls and Functions * ON indicates that the applicable bit signal is “1,” while OFF indicates that the bit si

Seite 148 - (PLCPCON)

4. SCON-CA 225 (5) Servo ON command (SON) [PLC output signal] Ready (SV) [PLC input signal] When the SON signal is turned ON, the servo will tur

Seite 149

4. SCON-CA 226 (6) Home return (HOME) [PLC output signal] Home return complete (HEND) [PLC input signal] Home return in progress (GHMS) [PLC in

Seite 150

4. SCON-CA 227 (7) Positioning start (CSTR): Used in the position/simple direct mode 1,2 [PLC output signal] The CSTR command is processed at the

Seite 151

4. SCON-CA 228 (10) Position complete signal (PEND) [PLC input signal] This signal turns ON after the actuator has moved to the target position and

Seite 152

4. SCON-CA 229 (12) Zone 1 (ZONE1) [PLC input signal] Zone 2 (ZONE2) [PLC input signal] Position zone (PZONE) [PLC input signal] Each signal tur

Seite 153

4. SCON-CA 230 (13) +Jog (JOG+) [PLC output signal] -Jog (JOG-) [PLC output signal] These signals are used as starting commands for jog operation

Seite 154 - Caution

4. SCON-CA 231 (14) Jog-speed/inch-distance switching (JVEL) [PLC output signal] This signal is used to switch between the jog speed parameter when

Seite 155 - 3.10 DeviceNet Parameters

4. SCON-CA 232 (16) Teaching command (MODE) [PLC output signal] Teaching mode signal (MODES) [PLC input signal] When the MODE signal is turned ON

Seite 156

4. SCON-CA 233 (19) Operation mode (RMOD) [PLC output signal] Operation mode status (RMDS) [PLC input signal] The operation mode is selected as s

Seite 157

2. ACON-C/CG, PCON-C/CG 18 2.7 Communicating with the Master Station 2.7.1 Operation Modes and Corresponding PLC I/O Areas The channel assignmen

Seite 158

4. SCON-CA 234 (23) Load missed in push motion (PSFL) [PLC input signal] This signal turns ON when the actuator has not contacted the load in push-

Seite 159

4. SCON-CA 235 (26) Load output judgment (LOAD) [PLC input signal] This signal is effective only during push-motion operation. To use the LOAD si

Seite 160 - 3.11 Troubleshooting

4. SCON-CA 236 (27) Torque level (TRQS) [PLC input signal] This signal is effective only during push-motion operation. If the motor current reach

Seite 161 - 3.12 CE Mark

4. SCON-CA 237 (28) Absolute Battery Voltage Low Warning (BALM) PLC Input Signal With an absolute system, this signal is OFF when the absolute b

Seite 162 - 4. SCON-CA

4. SCON-CA 238 (30) Acceleration/deceleration mode (MOD1, MOD0) [PLC output signal] These signals are used to select the acceleration/deceleration

Seite 163

4. SCON-CA 239 (31) Standstill Mode Selection (ASO0, ASO1) PLC Output Signals Select the stop mode to be applied while the actuator is standing

Seite 164

4. SCON-CA 240 *1 If the CLBR is turned OFF during this period, the signal is not recognized and therefore calibration is not perfor

Seite 165

4. SCON-CA 241 4.8 I/O Signal Timings The maximum response time after a given control signal is turned ON to operate the ROBO Cylinder using the P

Seite 166 - 4.2 Model Numbers

4. SCON-CA 242 4.9 Operation Next, timings in the position/simple direct mode 1, 2, half direct mode 1 to 3 and full direct mode are explained usi

Seite 167 - 4.3 Interface Specifications

4. SCON-CA 243 [1] [2] Set value of target position data Specified position number Positioni

Seite 168 - 4.4.1 Name of Each Part

2. ACON-C/CG, PCON-C/CG 19 x ACON or PCON output o PLC input side (* n indicates the node address of each axis.) ACON or PCON DO and output data

Seite 169

4. SCON-CA 244 (2) Operation in the half direct mode 1 to 3 Operate the actuator by specifying data for the PLC’s target position, positioning ban

Seite 170

4. SCON-CA 245 Set value of target position data [1] [2] [3] [4] [5] [6] [7] [8] [9] [10][14

Seite 171 - Push-motion

4. SCON-CA 246 (3) Operation in the full direct mode Operate the actuator by specifying from the PLC all conditions required for positioning, such

Seite 172

4. SCON-CA 247 Set value of target position data [1] [2] Set value of positioning band data Set value o

Seite 173

4. SCON-CA 248 [9] [10] Positioning band Push specification Push direction specification Positioning command

Seite 174

4. SCON-CA 249 (4) Data change during movement In the half direct mode 1 to 3 and full direct mode, the values of target position data, accelerati

Seite 175

4. SCON-CA 250 4.10 DeviceNet Parameters The parameters relating to DeviceNet are parameter Nos. 84 to 87, 90 and 159. Category: C: External inter

Seite 176

4. SCON-CA 251 z Network type (No. 87 NTYP) Specify the network module in parameter No. 87. Do not change the default value. z Fieldbus I/O form

Seite 177

4. SCON-CA 252 (Example ii) Set value = “1” z indicates ON, while O indicates OFF. SCON input register Hexade

Seite 178

4. SCON-CA 253 (Example iii) Set value = “2” z indicates ON, while O indicates OFF. SCON input register Hexad

Seite 179

2. ACON-C/CG, PCON-C/CG 20 2.7.2 Remote I/O Mode (Number of Occupied Channel: 1) In this mode, the actuator is operated by specifying position num

Seite 180

4. SCON-CA 254 (Example iv) Set value = “3” z indicates ON, while O indicates OFF. z FB Half Direct Mode Spee

Seite 181

4. SCON-CA 255 4.11 Troubleshooting z Alarm messages, causes and remedial actions If an alarm occurs, a corresponding simple alarm code will be i

Seite 182

5. Troubleshooting 256 5. Troubleshooting If you encountered a problem concerning DeviceNet, check the operating condition using the table below a

Seite 183

6. Change History 257 6. Change History Revision Date Description of Revision November 2011 June 2012 November 2012 First edition C

Seite 186

Manual No.: ME0256-3B (November 2012)The information contained in this document is subject to change without notice for purposes ofproduct improvem

Seite 187

2. ACON-C/CG, PCON-C/CG 21 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 ACON or PCON DI (port nu

Seite 188

2. ACON-C/CG, PCON-C/CG 22 (3) I/O signal assignments The signals assigned to the controller’s I/O ports vary depending on the setting of paramete

Seite 189

2. ACON-C/CG, PCON-C/CG 23 Setting of Parameter No. 25 512-point mode Solenoid mode 1 Solenoid mode 2 3 4 5 Category Port No. Symbol Signal

Seite 190

Please Read Before Use Thank you for purchasing our product. This Operation Manual explains the handling methods, structure and maintenance of

Seite 191

2. ACON-C/CG, PCON-C/CG 24 Setting of Parameter No. 25 Positioning mode (standard) Teaching mode (teaching type) 256-point mode (256-point type)

Seite 192

2. ACON-C/CG, PCON-C/CG 25 Setting of Parameter No. 25 512-point mode Solenoid mode 1 Solenoid mode 2 3 4 5 Category Port No. Symbol Signal

Seite 193

2. ACON-C/CG, PCON-C/CG 26 2.7.3 Position/Simple Direct Mode (Number of Occupied Channels: 4) In this mode, the actuator is operated by specifying

Seite 194

2. ACON-C/CG, PCON-C/CG 27 1 word (channel) = 16 bitsTarget position (lower word) Target position (upper word) If the target position is a negative

Seite 195

2. ACON-C/CG, PCON-C/CG 28 1 word (channel) = 16 bits Current position (lower word) Current position (upper word) Completed position number Status

Seite 196

2. ACON-C/CG, PCON-C/CG 29 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the b

Seite 197

2. ACON-C/CG, PCON-C/CG 30 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bit

Seite 198

2. ACON-C/CG, PCON-C/CG 31 2.7.4 Half Direct Mode (Number of Occupied Channels: 8) In this mode, the target position, positioning band, speed, acc

Seite 199 - Deceleration

2. ACON-C/CG, PCON-C/CG 32 (2) I/O signal assignments for each axis The I/O signals of each axis consist of eight input words (channels) and eight

Seite 200

2. ACON-C/CG, PCON-C/CG 33 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative

Seite 201

Caution: The following functions are described in the separate operation manual. Title of operation manual/Overview Control number 1 Device

Seite 202

2. ACON-C/CG, PCON-C/CG 34 PLC input Channel (* n indicates the node address of each axis.) 1

Seite 203

2. ACON-C/CG, PCON-C/CG 35 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the b

Seite 204

2. ACON-C/CG, PCON-C/CG 36 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bit

Seite 205

2. ACON-C/CG, PCON-C/CG 37 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bit

Seite 206

2. ACON-C/CG, PCON-C/CG 38 2.7.5 Full Direct Mode (Number of Occupied Channels: 16) In this mode, the actuator is operated by specifying all value

Seite 207

2. ACON-C/CG, PCON-C/CG 39 (2) I/O signal assignments for each axis The I/O signals of each axis consist of sixteen input words (channels) and six

Seite 208

2. ACON-C/CG, PCON-C/CG 40 1 word (channel) = 16 bits Target position (lower word) Target position (upper word) If the target position is a negative

Seite 209

2. ACON-C/CG, PCON-C/CG 41 Channel (* n indicates the node address of each axis.) (*1) Signal ass

Seite 210

2. ACON-C/CG, PCON-C/CG 42 PLC input Channel (* n indicates the node address of each axis.) (

Seite 211

2. ACON-C/CG, PCON-C/CG 43 (3) I/O signal assignments (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the b

Seite 212

Table of Contents Safety Guide...

Seite 213

2. ACON-C/CG, PCON-C/CG 44 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Sym

Seite 214

2. ACON-C/CG, PCON-C/CG 45 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Address Bits Sym

Seite 215

2. ACON-C/CG, PCON-C/CG 46 (* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”) Signal type Bit

Seite 216

2. ACON-C/CG, PCON-C/CG 47 2.7.6 Remote I/O Mode 2 (Number of Occupied Channels: 6) In this mode, the actuator is operated by specifying position

Seite 217

2. ACON-C/CG, PCON-C/CG 48 (1) PLC channel configuration (* n indicates the node address of each axis.) Parameter No. 84 ACON or PCON DI and input

Seite 218

2. ACON-C/CG, PCON-C/CG 49 1 word (channel) = 16 bits Controller output port number Not available. Current position (lower word) Current position (u

Seite 219

2. ACON-C/CG, PCON-C/CG 50 (3) I/O signal assignments For the signal assignments corresponding to each PIO pattern, refer to the I/O signal assign

Seite 220

2. ACON-C/CG, PCON-C/CG 51 2.7.7 I/O Signal Controls and Functions * ON indicates that the applicable bit signal is “1,” while OFF indicates that

Seite 221

2. ACON-C/CG, PCON-C/CG 52 (5) Servo ON command (SON) [PLC output signal] Ready (SV) [PLC input signal] When the SON signal is turned ON, the se

Seite 222

2. ACON-C/CG, PCON-C/CG 53 (6) Home return (HOME) [PLC output signal] Home return complete (HEND) [PLC input signal] Home return in progress (GH

Seite 223

3.7 Communicating with the Master Station ... 91 3.7.1 Operat

Seite 224

2. ACON-C/CG, PCON-C/CG 54 (7) Positioning start (CSTR): Used in the position/simple direct mode [PLC output signal] The CSTR command is processed

Seite 225

2. ACON-C/CG, PCON-C/CG 55 (10) Position complete signal (PEND) [PLC input signal] This signal turns ON after the actuator has moved to the target

Seite 226

2. ACON-C/CG, PCON-C/CG 56 (12) Zone 1 (ZONE1) [PLC input signal] Zone 2 (ZONE2) [PLC input signal] Position zone (PZONE) [PLC input signal] Eac

Seite 227

2. ACON-C/CG, PCON-C/CG 57 (13) +Jog (JOG+) [PLC output signal] -Jog (JOG-) [PLC output signal] These signals are used as starting commands for j

Seite 228

2. ACON-C/CG, PCON-C/CG 58 (14) Jog-speed/inch-distance switching (JVEL) [PLC output signal] This signal is used to switch between the jog speed pa

Seite 229

2. ACON-C/CG, PCON-C/CG 59 (16) Teaching command (MODE) [PLC output signal] Teaching mode signal (MODES) [PLC input signal] When the MODE signal

Seite 230

2. ACON-C/CG, PCON-C/CG 60 (19) Operation mode (RMOD) [PLC output signal] Operation mode status (RMDS) [PLC input signal] The operation mode is s

Seite 231

2. ACON-C/CG, PCON-C/CG 61 (23) Load missed in push motion (PSFL) [PLC input signal] This signal turns ON when the actuator has not contacted the l

Seite 232

2. ACON-C/CG, PCON-C/CG 62 (26) Load output judgment (LOAD) [PLC input signal] [Dedicated PCON function] This signal is effective only during push-

Seite 233

2. ACON-C/CG, PCON-C/CG 63 (27) Torque level (TRQS) [PLC input signal] [Dedicated PCON function] This signal is effective only during push-motion o

Seite 234

1 Safety Guide “Safety Guide” has been written to use the machine safely and so prevent personal injury or property damage beforehand. Make sure t

Seite 235

2. ACON-C/CG, PCON-C/CG 64 (28) Stopping control mode (SMOD) [PLC output signal] [Dedicated PCON function] One general characteristic of pulse moto

Seite 236

2. ACON-C/CG, PCON-C/CG 65 (29) Acceleration/deceleration mode (MOD1, MOD0) [PLC output signal] [Dedicated ACON function] These signals are used

Seite 237

2. ACON-C/CG, PCON-C/CG 66 (30) Stop Mode Selection (ASO1, ASO0) [PLC Output Signal] Select the stop mode for the duration before the movement to t

Seite 238

2. ACON-C/CG, PCON-C/CG 67 2.8 I/O Signal Timings The maximum response time after a control signal is turned ON to operate the ROBO Cylinder in a

Seite 239

2. ACON-C/CG, PCON-C/CG 68 2.9 Operation This section describes the timings of basic operations in the position/simple direct mode, half direct mo

Seite 240

2. ACON-C/CG, PCON-C/CG 69 Set value of target position data [1] [2] [3] [4] [5][6] Specified posit

Seite 241

2. ACON-C/CG, PCON-C/CG 70 (2) Operation in the half direct mode The actuator is operated by specifying the data to the target position channel, p

Seite 242

2. ACON-C/CG, PCON-C/CG 71 [1] [2] [3] [4] [5] [6] [7] [8] [9] [10][14][13][12][11] *T1: Make sure “T1 t 0 ms” is satisfied by considering the scan

Seite 243

2. ACON-C/CG, PCON-C/CG 72 (3) Operation in the full direct mode The actuator is operated by specifying all conditions required for positioning to

Seite 244

2. ACON-C/CG, PCON-C/CG 73 Set value of target position data Set value of positioning band data Set value of speed data Set value of push-motion cur

Seite 245 - Target position

2 No. Operation Description Description 2 Transportation  When carrying a heavy object, do the work with two or more persons or utilize equipm

Seite 246

2. ACON-C/CG, PCON-C/CG 74 Current position Moving Push-motion specification Push direction specificatio

Seite 247 - 4.8 I/O Signal Timings

2. ACON-C/CG, PCON-C/CG 75 Set value of speed or acceleration/deceleration Actuator speed Speed n2Speed n3 [1] [2][3] (4) Data change during moveme

Seite 248 - 4.9 Operation

2. ACON-C/CG, PCON-C/CG 76 2.10 DeviceNet Parameters Parameters relating to DeviceNet are Nos. 84 to 87 and 90. Category: C: External interface pa

Seite 249

2. ACON-C/CG, PCON-C/CG 77 z Network type (No. 87, NTYP) The network module type is specified in parameter No. 87. Do not change the default setti

Seite 250

2. ACON-C/CG, PCON-C/CG 78 (Example ii) Set value = “1” z indicates ON, while O indicates OFF. Input register

Seite 251

2. ACON-C/CG, PCON-C/CG 79 Input register Hexa decimal data Output channel Hexa decimal data Output register Input channel Hexa decimal data Hexa d

Seite 252

2. ACON-C/CG, PCON-C/CG 80 (Example iv) Set value = “3” z indicates ON, while O indicates OFF. Input register H

Seite 253

2. ACON-C/CG, PCON-C/CG 81 2.11 Troubleshooting z Alarm messages, causes and remedial actions If an alarm occurs, a corresponding simple alarm co

Seite 254

2. ACON-C/CG, PCON-C/CG 82 2.12 CE Mark If a compliance with the CE Marking is required, please follow Overseas Standards Compliance Manual (ME028

Seite 255

3. PCON-CA/CFA 83 PLC PLC Flat cable Communication cable 3. PCON-CA/CFA 3.1 Operation Modes and Functions PCON-CA/CFA controllers supporting Dev

Seite 256 - 4.10 DeviceNet Parameters

3 No. Operation Description Description (2) Cable Wiring  Use our company’s genuine cables for connecting between the actuator and controller, a

Seite 257

3. PCON-CA/CFA 84 [2] Position/simple direct mode: In this mode, the actuator is operated by specifying position numbers. You can select whether t

Seite 258

3. PCON-CA/CFA 85 䎳䎯䎦䎃PLC PLCFlat cable Communication cable [4] Full direct mode: In this mode, the actuator is operated by specifying all values

Seite 259

3. PCON-CA/CFA 86 3.2 Model Numbers The model numbers of PCON-CA/CFA controller supporting DeviceNet are indicated as follows, respectively: z PC

Seite 260

3. PCON-CA/CFA 87 3.3 Interface Specifications Item Specification DeviceNet 2.0 Group 2 only server Communication protocol Network-powered isolati

Seite 261 - 4.11 Troubleshooting

3. PCON-CA/CFA 88 3.4 DeviceNet Interface 3.4.1 Name of Each Part The name of each part relating to DeviceNet is shown.

Seite 262 - 5. Troubleshooting

3. PCON-CA/CFA 89 3.4.2 Monitor LED Indicators The two LEDs, MS and NS, provided on the front panel of the controller are used to check the node (

Seite 263 - 6. Change History

3. PCON-CA/CFA 90 3.5 Selecting (Setting) the Operation Mode The operation mode is set using a parameter. Set the mode selector switch on the fro

Seite 264

3. PCON-CA/CFA 91 3.7 Communicating with the Master Station 3.7.1 Operation Modes and Corresponding PLC I/O Areas The channel assignments in eac

Seite 265

3. PCON-CA/CFA 92 x PCON-CA/CFA output o PLC input side (* n indicates the node address of each axis.) PCON-CA/CFA DO and output data register Rem

Seite 266 - 12.11.000

3. PCON-CA/CFA 93 3.7.2 Remote I/O Mode (Number of Occupied Channel: 1) In this mode, the actuator is operated by specifying position numbers, jus