Iai-america PCON-CFA Bedienungsanleitung Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 266
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
2. ACON-C/CG, PCON-C/CG
11
[2] Position/simple direct mode: In this mode, the actuator is operated by specifying position numbers.
You can select whether to specify the target position directly as a value, or use
a value registered in the position data table, by switching a control signal.
For the speed, acceleration/deceleration, positioning band, etc., values
preregistered in the position data table are used. Up to 768 position data points
can be set.
Number of occupied bytes: 4CH
[3] Half direct mode: In this mode, the actuator is operated by specifying the speed, acceleration/deceleration
and push current, in addition to the target position, directly as values.
Number of occupied bytes: 8CH
PLC
Target position: 100.00 mm
+
Position No. 0
CON/PCON supporting
DeviceNet
A
ctuato
r
S
p
eed
A
cceleration
Deceleration
Push
PLC
Target position: 100.00 mm
Positioning band: 0.10 mm
Speed specification: 100.0
mm/sec
A
cceleration/deceleration:
0.30 G
Push current: 50%
CON/PCON supporting
DeviceNet
A
ctuato
r
Seitenansicht 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 265 266

Kommentare zu diesen Handbüchern

Keine Kommentare