Iai-america ERC2 Bedienungsanleitung Seite 32

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 138
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 31
22
1. Overview
13
Actuator with
integrated
controller
Other
equipment
Other
equipment
Actuator with
integrated
controller
1.8.3 Power Supply
The control/motor-drive power supply specification is 24 VDC r 10% (2 A max).
1.8.4 Noise Elimination
This section explains how to eliminate noise in the use of the controller.
(1) Wiring and power supply
[1] Provide a dedicated class D grounding using a wire with a size of 0.75 mm
2
or larger.
Class D grounding Good Avoid this
grounding method.
[2] Precautions regarding wiring method
Wire extension cables separately from high-power lines for power circuits, etc. (Do not bundle them
together or place them in the same cable duct.)
Seitenansicht 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 137 138

Kommentare zu diesen Handbüchern

Keine Kommentare