Part 1 Installation
2. Explanation of Codes Displayed on the Panel Window
2.1. Application
1
AC power is cut off (including momentary power failure or drop in
power-source voltage).
1 System-down level error
2 Writing data to the flash ROM.
3 Emergency stop is being actuated (except during the update mode).
4 Safety gate is open (except during the update mode).
5 Cold-start level error
5 Cold-start level error
5 Operation-cancellation level error
5 Operation-cancellation level error
6
Waiting for a drive-source cutoff reset input (except during the
update mode).
6
Operation is in pause (waiting for restart) (except during the update
mode).
7 All servo axes are interlocked (except during the update mode).
8 Message level error
8 Message level error
9 Core update mode
9 Core update is in progress.
9 Core update has completed.
9 Slave update mode
9 Slave update is in progress.
9 Slave update has completed.
9
Running a program (last started program); “No.” indicates program
number.
9 Initialization sequence number
9 Debug mode
9 Ready status (auto mode)
9 Ready status (manual mode)
10 Deadman switch OFF (manual mode)
(*1) The priority increases as the number decreases.